Ablation Model
Ablation Model

Ablation Model

Ablation

This model facilitates technical training for catheter manipulation and 3D mapping, which are basic skills required for catheter ablation. With this model, the Brockenbrough Method guided by ICE can also be simulated.

The model is appropriate for both the internal jugular and femoral vein approach.

Atrial septal puncture

Atrial septal puncture
Atrial septal puncture
Atrial septal puncture

3D mapping

3D mapping
3D mapping
3D mapping

- Basic Set -

Ablation Model

Heart model for Ablation

This model has an atrial septum which can be punctured repeatedly. The septal part can be replaced. Please contact JMC for details.

Special Tank

Special Tank

Transparent tank that provides high visibility for catheter use simulation with or without X-ray fluoroscopy. No more than six liters of water are required for training.

Pulsatile Pump

Pulsatile Pump

Our uniquely-developed pulsatile pump can be set by 30-120 bpm (1600-4000ml/min in flow volume.). Realistic coronary images are obtained by particular patterns of the cylinder movement. The pump and tank are connected with easy-to-prepare connectors to avoid water leaks and time losses.

Dryseal sheath

Dryseal sheath

Special Dryseal sheath.
Number of tubes: 1( 24Fr )

Lubricant

Lubricant

Special lubricant for coating the inner surface of the heart model.
1 fl. oz. ( lasts for 20 coatings )

Hoses

Hoses

Hose with one-touch joint.


- Basic Set -

Heart Model for Disease

Heart Model for Disease

A heart model suitable for practical training in CAG and PCI under X-ray fluoroscopy in the cath lab. Stent deployment and guide wire manipulation can be simulated with this model.

Special Tank

Special Tank

Transparent tank that provides high visibility for catheter use simulation with or without X-ray fluoroscopy. No more than six liters of water are required for training.

Pulsatile Pump

Pulsatile Pump

Our uniquely-developed pulsatile pump can be set by 30-120 bpm (1600-4000ml/min in flow volume.). Realistic coronary images are obtained by particular patterns of the cylinder movement. The pump and tank are connected with easy-to-prepare connectors to avoid water leaks and time losses.

Dryseal sheath

Dryseal sheath

Special Dryseal sheath.
Number of tubes: 1( 24Fr )

Lubricant

Lubricant

Special lubricant for coating the inner surface of the heart model.
1 fl. oz. ( lasts for 20 coatings )

Hoses

Hoses

Hose with one-touch joint.

Product specifications can be customized and are subject to change without notice. Please contact JMC for details.

Contact