CTO Model
CTO Model

CTO Model

Coronary

This is a chronic total occlusion disease model. It features multiple collateral channels between LAD and RCA, and between LCX and RCA. The LAD, LCX and RCA have their own pockets, so that if the CTO vessel part is set in the RCA pocket, both the antegrade approach from RCA and the retrograde approach from LAD can be simulated, and vice versa.

CTOモデル

Occlusion vessels can be selected by changing the position of the replaceable coronary artery part.

CTO Model
CTO Model

- Basic Set -

CTO Model

Heart Model for CTO

Heart Model for CTO

A heart model suitable for practical training in CAG and PCI under X-ray fluoroscopy in the cath lab. Stent deployment and guide wire manipulation can be simulated with this model.

Special Tank

Special Tank

Transparent tank that provides high visibility for catheter use simulation with or without X-ray fluoroscopy. No more than six liters of water are required for training.

Pulsatile Pump

Pulsatile Pump

Our uniquely-developed pulsatile pump can be set by 30-120 bpm (1600-4000ml/min in flow volume.). Realistic coronary images are obtained by particular patterns of the cylinder movement. The pump and tank are connected with easy-to-prepare connectors to avoid water leaks and time losses.

Tubes with Sheath

Tubes with Sheath

Special tubes with sheath.
Number of tubes: 2( 6・8Fr )

Lubricant

Lubricant

Special lubricant for coating the inner surface of the heart model.
1 fl. oz. ( lasts for 20 coatings )

Hoses

Hoses

Hose with one-touch joint.


- Basic Set -

CTO Model

Heart Model for CTO

Heart Model for CTO

A heart model suitable for practical training in CAG and PCI under X-ray fluoroscopy in the cath lab. Stent deployment and guide wire manipulation can be simulated with this model.

Special Tank

Special Tank

Transparent tank that provides high visibility for catheter use simulation with or without X-ray fluoroscopy. No more than six liters of water are required for training.

Pulsatile Pump

Pulsatile Pump

Our uniquely-developed pulsatile pump can be set by 30-120 bpm (1600-4000ml/min in flow volume.). Realistic coronary images are obtained by particular patterns of the cylinder movement. The pump and tank are connected with easy-to-prepare connectors to avoid water leaks and time losses.

Tubes with Sheath

Tubes with Sheath

Special tubes with sheath.
Number of tubes: 2( 6・8Fr )

Lubricant

Lubricant

Special lubricant for coating the inner surface of the heart model.
1 fl. oz. ( lasts for 20 coatings )

Hoses

Hoses

Hose with one-touch joint.

Product specifications can be customized and are subject to change without notice. Please contact JMC for details.